Two figures in the specification sheets and the manuals have to do with differential pressure: the TYA documentation says that a pressure >0.3 MPa means the elements must be cleaned or changed, and the differential pressure alarm value of the 150-500-5 fine element on the ZYD series is 0.35 MPa. The two numbers look close, yet they do not govern the same thing, and reading them as one leads to the wrong action on site.
Start by separating what each of them describes. The 0.3 MPa figure sits on the equipment side: it is read from the pressure gauge at the outlet and shows how much resistance the whole oil circuit is presenting at that moment. The 0.35 MPa figure sits at the fine element: it is the differential pressure across the element inlet and outlet and shows how much resistance that group of elements is taking on itself. Different position, different physical meaning, different action once the limit is reached.
Why the two numbers are never the same
On a machine, between the outlet of the oil pump and the oil outlet, several resistances sit in series: coarse filtration, the second stage and the fine filtration. In the filtration configuration of the ZYD-100 the coarse elements are of the 150-250-50 and 110-250-50 type, the second stage element is 110-400-20, the fine elements come as 110-600-5 and 150-500-5, and the standard configuration is 5 pieces of 150-500-5 in parallel. As soon as one of these sections starts to load up, the outlet pressure rises, while the differential pressure of the fine group is only a part of the total resistance. The other way round, if the fine elements are blocked while the sections in front of them are still clean, the outlet pressure may only creep up a little while the differential pressure is already clearly visible.
The division of labour is therefore this: the outlet pressure tells you whether the machine can still deliver at its rated flow rate, and the differential pressure across the fine elements tells you how much life is left in that last filtration stage. The two readings support each other, but neither replaces the other.

| Reading | What it describes | What to do once the limit is passed |
|---|---|---|
| TYA outlet pressure >0.3 MPa | The reading of the outlet pressure gauge | Clean or change the filter elements as the documentation requires; on a TYA with automatic backwash, run one backwash cycle first |
| Fine element differential pressure alarm at 0.35 MPa | The differential pressure across the 150-500-5 element group | Prepare to replace that group of fine elements, and check how the differential pressure is shared with the other sections |
| Vacuum level sitting at the -0.08 MPa end | The negative pressure in the degassing stage | Rule out an excessive gas load and residual liquid in the pipework before suspecting the pump group |
What to record along with a differential pressure
A differential pressure on its own is an isolated number and only means something next to the conditions at the time. Whenever the reading is copied down, write down the oil temperature at the same moment, the type of this batch of oil, how long the machine has been running, and the reading recorded last time under similar conditions; without one of those four, the later comparison cannot be made.
Keep in mind in particular that 6000 L/h is a figure for rated conditions. Once the differential pressure rises the actual flow rate falls, and the same differential pressure corresponds to a different flow rate at a different oil temperature. Record the differential pressure without the oil temperature and, when the elements are changed and the figures are looked at again, normal wear will be read as a fault.
What to do when the differential pressure rises
A rising differential pressure does not mean the element has reached the end of its life, and it does not mean the pump has to be changed. The correct order is to fix the conditions first and compare afterwards: on the same machine, with the same batch of oil, at a similar oil temperature and flow rate, put this reading next to the one recorded last time. If the differential pressure jumped in one step, the usual causes are a damaged element, a bypass that was not sealed properly, or foreign matter caught at the inlet; if it climbs slowly with the volume processed, the media is simply taking up dirt as it should.
- Do not raise the alarm setting after a differential pressure alarm: once the setting is raised, the protection that stops the machine on overpressure has lost its meaning.
- Do not change elements without looking at the oil: oil carrying water makes the media resistance rise faster, so the same differential pressure does not stand for the same amount of retained dirt.
- Do not work backwards from the rated flow rate to the differential pressure: 6000 L/h is a number for rated conditions, and the same applies to the 2000 L/h of the TYA-50 and the 4000 L/h of the TYA-100; the actual flow rate follows the differential pressure and the oil temperature, so the pressure gauge and the flow meter have to be read together.
The 0.3 MPa figure governs whether the machine can still deliver oil smoothly; the 0.35 MPa figure governs whether that group of fine elements can keep working. Each stands on its own, and mixing them leads to the wrong action.