The page most often turned past in a set of random documents is the one carrying the operating conditions or the installation requirements. It is not long and it is not difficult to read, yet it decides whether the machine will work properly once it reaches the site. Three of those items are worth taking out on their own: the ambient temperature, the altitude and the power supply.
The temperature is written as -20–45 °C. That range defines the environment in which the machine works reliably: at low temperature the viscosity of the vacuum pump oil rises and the pumping speed falls, so it takes longer to reach the same vacuum level; at high temperature the control cabinet has to shed heat, and the machine room needs good ventilation and protection against damp. The temperature is not better the higher or the lower it is; it lies in a range, and outside that range the machine either loses efficiency or needs additional protection.
Altitude is directly linked to the vacuum level. The higher the altitude, the lower the atmospheric pressure, and the lower the ultimate absolute pressure the same pump group can reach on site; the reading of the negative pressure moves with it. The TYA-100 documentation puts it plainly: the higher the altitude, the lower the negative value of the vacuum. The site altitude therefore has to be stated at the selection stage, instead of waiting until the machine is on site and the vacuum will not come up, and then suspecting the machine itself.
The supply is three-phase 380V / 50Hz. The total power of the ZYD-100 is 72 + 5 kW and the installed capacity is prepared from the sum of the two figures, so a site with a single-phase supply cannot connect this machine; and the 50 Hz premise does not necessarily hold where the machine runs on a generator, because a generator set running off frequency shifts the speed of the pumps and with it the pumping speed.

| Condition | How it is written in the documents | What happens on site if it is not met | How to check it |
|---|---|---|---|
| Ambient temperature | -20–45 °C | Lower temperature slows the pumping speed and lengthens the heating time; higher temperature brings cabinet temperature rise and condensation | Ask for the actual winter and summer temperature and keep it in the log |
| Site altitude | The higher the altitude, the lower the negative value of the vacuum | The same pump group cannot reach the expected negative pressure | Put the altitude into the technical agreement at the selection stage |
| Power supply | Three-phase 380V / 50Hz | Single phase cannot be connected; a frequency deviation shifts the pump speed | Check the distribution capacity against the total power of 72 + 5 kW |
| Earthing and damp protection | The machine room needs good ventilation and protection against damp | Condensation and insulation risk | Record each item during the electrical acceptance check |
Which stage each condition reaches into
The temperature reaches into the heating and the vacuum stages. At low temperature the viscosity of the vacuum pump oil rises and the pumping speed falls, and the heating stage needs longer to bring the oil to the set point; at high temperature the control cabinet has to shed heat, and poor ventilation in the machine room shows up directly as temperature rise and condensation inside the cabinet. The working vacuum of the TYA series is -0.08 MPa, the temperature control range is 45–80 °C and the upper limit is pressed down to 70 °C for oil with a high water content, and these figures hold inside that ambient temperature range.
Altitude reaches into the vacuum stage. The higher the altitude, the lower the atmospheric pressure and the lower the ultimate absolute pressure the pump group can reach, so whether the working vacuum of -0.08 ~ -0.0999 MPa can be held on site depends on the altitude of the site. The power supply reaches into starting and protection. Three-phase 380V / 50Hz is the condition for the machine to run at its rated parameters, and phase loss and phase sequence protection are the first line of defence in that part of the machine.
Which pages to turn first at handover
The information on the operating conditions is usually spread across several places in the random documents: the technical parameters page carries the rated conditions, the installation and storage notes carry the environmental requirements, the wiring diagram shows the supply specification and the earthing, and the spare parts and wear parts list gives the maintenance intervals and the basis for replacement. Read them in that order and a document of a few dozen pages takes a quarter of an hour, which is far less time than looking for the same information again on site.
Write these three into your own log
- Write down the actual altitude of the site, not just the name of the province.
- Write down the phase, the voltage and the frequency of the supply; where a generator is used, write down the range the frequency varies over.
- Write down the winter and summer temperature of the room the machine stands in, together with the ventilation and dehumidification arrangements.
- When the random documents are handed over, turn every page, and copy the pages that relate to the site into your own file.

The operating conditions in the random documents are not formalities: with the temperature, the altitude and the power supply known in advance they can be adapted in advance, and without them there is nothing left to do but improvise on site.