In everyday speech on site, degassing, dewatering and filtration are used as if they were interchangeable, and sometimes two of them appear in the same sentence. The mix-up does not affect the running of the machine, but it does distort the conversation: it leads to the belief that once the gas has been removed the water no longer matters, or that a fine filtration accuracy means the cleanliness is good. What follows sorts out the technical meaning of the three words and the process step each of them belongs to.

The two mix-ups that come up most often

One is using degassing to mean pulling a vacuum. When the site says the degassing of a machine is not working, what is often meant is that the vacuum level will not come up, and that can come from the pump group, from the sealing of the pipework or from an excessive gas load at the inlet, none of which is the same as degassing efficiency. The other is setting filtration accuracy against cleanliness: the first is the size of particle the media can hold back, the second is how many particles are actually in the oil, and the relation between the two can only be established by measurement.

Degassing is the removal of gas dissolved in the oil. It is reported as the gas content, referenced to GB/T 423, with a requirement of ≤0.01%. Water, water vapour and hydrocarbon gases differ in boiling point and in how they dissolve, so degassing depends on two conditions being met together: heating lowers the solubility, and the negative pressure lets the gas escape. The working vacuum of the ZYD-100 is -0.08 ~ -0.0999 MPa, the ultimate vacuum ≤5 Pa and the temperature control range is 45–80 °C, with the upper limit pressed down to 70 °C for oil with a high water content; these figures together set what the degassing can achieve.

Dewatering is the removal of water, reported as the water content, referenced to GB/T 7600, with a requirement of ≤3 ppm. Water exists in oil in two forms, dissolved and emulsified; emulsified water is held inside solid particles and surfactant, and pulling it out of the emulsified state by vacuum is far harder than vapourising dissolved water, so how well the pretreatment was done decides how difficult the dewatering turns out to be.

Filtration is the holding back of solid particles, and it is reported through two indicators: the filtration accuracy of ≤1 μm is the nominal capability of the media, and the cleanliness of NAS 1638 class 5 is the class corresponding to the number of particles actually in the oil. The ZYD-100 uses a 50 μm stage to hold back large particles and a deep-bed fine filtration of 1–5 μm to collect the fine ones.

Heating section and oil circuit of a vacuum oil purifier
The heating and the vacuum conditions are shared, so dewatering and degassing happen in the same process step
Term used on siteTechnical meaningProcess stepIndicator and reference
DewateringTaking the water out of the oilHeating to vapourise and negative pressure to draw it offWater content ≤3 ppm (GB/T 7600)
DegassingTaking dissolved gas and hydrocarbons outHeating to lower the solubility and negative pressure to draw it offGas content ≤0.01% (GB/T 423)
FiltrationHolding back solid particlesCoarse filtration and deep-bed fine filtration in stagesFiltration accuracy ≤1 μm, cleanliness NAS 1638 class 5

Why the documentation keeps dewatering and degassing together

Because in one vacuum machine the two happen at the same time. Water can only leave the oil as vapour, and gas can only escape under negative pressure, and the heating and the vacuum are the two conditions both of them need. So dewatering and degassing describes one process step solving two kinds of problem, and it does not mean that the machine is responsible for one of them only.

The same is visible on a test report: a complete report should show four lines, the water content, the gas content, the breakdown voltage and the cleanliness, each with its reference standard. If one line is missing, that part of the process has not been assessed, and the remaining lines cannot be used to infer it.

How many lines a report should have

A complete comparison has four lines: water content (GB/T 7600), gas content (GB/T 423), breakdown voltage (GB/T 507) and cleanliness (NAS 1638). Each line corresponds to a process step that has been assessed; a missing line means that step was not assessed. When a report arrives with only one or two lines on it, the question to ask is whether the other indicators were not tested or did not meet the requirement.

  • Using pulling a vacuum as a synonym for degassing: pulling a vacuum is the means, the gas content is the result.
  • Taking filtration accuracy for cleanliness: the first is the capability of the media, the second is the number of particles actually in the oil.
  • Taking a single qualified result as a permanently qualified one: the indicators move with the state of the oil, so the trend is what matters.
Vacuum oil purifier with five parallel fine elements and the electrical control cabinet
A degassing stage and a filtration stage sit in the same machine, and their results are assessed by different indicators
Degassing, dewatering and filtration correspond to the gas content, the water content and the cleanliness; once the wording is aligned, the handover and the accounting do not drift apart.