Three gauges do most of the work on site: the oil temperature, the vacuum gauge and the pressure gauge. Most people watch whichever one belongs to the job in front of them, and when something goes wrong that is exactly how the direction gets misjudged. Reading the three together is more effective, because each belongs to one of the three stages inside the machine, and whichever moves first tells you where the fault sits.
The oil temperature belongs to the heating stage. The temperature control range of the TYA series is 45–80 °C, with the upper limit pressed down to 70 °C for oil with a high water content, and the ZYD-100 uses far-infrared carbon fibre heating. The vacuum gauge belongs to the degassing stage, where the working vacuum is -0.08 ~ -0.0999 MPa and the ultimate vacuum ≤5 Pa. The pressure gauge belongs to the filtration stage, and it is this line that the audible and visual overpressure alarm and shutdown protect.
Which stage each reading belongs to
Separating the three stages is what makes the judgement possible. In the heating stage the question is whether the set temperature is reached and whether it then holds steady; in the degassing stage it is whether the negative pressure can be built and whether it holds once built; in the filtration stage it is how high the pressure has climbed and how much flow is left. The three interact, but each has its own separate behaviour, and reading them apart keeps one from distorting the others.

| The reading that moves first | Where the problem probably sits | What to check next |
|---|---|---|
| The oil temperature rises slowly and never reaches the set value | The heating stage | Scaling on the heat transfer surface, the quantity of oil in the tank, whether the oil flows past the temperature probe properly |
| Oil temperature and pressure are normal, the vacuum level stays at the shallow end | The vacuum stage | Gas load and oil mist at the inlet, the pump group and the sealing of the pipework, residual liquid in the chamber |
| Vacuum level and oil temperature are steady, the pressure climbs step by step | The filtration stage | Dirt loading in the elements, media wetted by water, whether the end cap is sealed properly |
| All three move and the oil temperature moves first | Most likely not a machine fault | First check the quantity of oil, the batch of oil and the setpoints for any change |
When two readings move together, which one to look at first
There is a coupling between oil temperature and pressure that is easy to misread: the viscosity of the oil changes with temperature, and as the temperature falls the resistance at the same flow rate rises, so the pressure gauge follows it up. That is easily taken for a blocked element. The other way round, as the temperature rises the resistance falls and the pressure drops, which is just as easily taken for a clear element. A change in pressure therefore has to be read together with the oil temperature at the same moment; the trend of the pressure gauge on its own leads nowhere.
Flow rate follows the same rule. The rated flow rate of 6000 L/h is a figure for given conditions: as the oil temperature and the differential pressure change, the actual throughput changes with them, and none of that shows on the pressure gauge. To confirm the throughput you need a flow meter or a count over the processing time.

Write the three numbers down together
- Copy the three numbers at one moment: oil temperature, pressure and vacuum level, not three separate moments.
- Write the conditions down with them: the type of this batch of oil, how much oil is in the machine, how long it has been running, and what the same three numbers were on the previous batch.
- Keeping the record across several batches is worth more than any single observation: a trend separates a machine that is slowly going off from one batch of oil that was unusually dirty.
- The moment an alarm operates, all three readings are there. Copy them down before touching anything.
The three gauges are not three independent readings; they stand for the heating, vacuum and filtration stages, and whichever one moves first has already settled half of the diagnosis.