The result of the vacuum degassing step depends on two things holding at the same time: the vacuum level in the chamber has to be deep enough, and the temperature of the oil entering it has to be high enough. On site these two are often handled separately - one person watches the vacuum gauge, another watches the temperature display - and the result is a familiar one: the pressure reading looks healthy while the water content refuses to fall.

This is usually not a fault of the machine. It is the two settings that have not been matched to each other. The vacuum level and the heating temperature are a pair in the degassing process, and each of them answers a different question.

The vacuum level decides where the water goes

Water is present in the oil in the dissolved state. The lower the pressure above the oil, the lower the boiling point of water, and the easier it is for the water to leave the oil. The working vacuum of the ZYD series is written as -0.08 ~ -0.0999 MPa, the range of negative pressure the chamber can establish and hold while it runs; the ultimate vacuum of ≤5 Pa is the lowest pressure the system can reach, measured with the system pumped down to its limit. Holding the working vacuum above -0.08 MPa during operation is what gives the water dissolved in the oil a chance to leave it.

The other way round makes it clear: if the vacuum level stays near the shallow end of the range, the boiling point of water is still high, less water travels into the oil vapour mixture, and the real load on the degassing stage never comes up. On site this shows as a vacuum gauge that reads shallow and never gets deeper, however long it waits.

The heating temperature decides whether the oil can be atomised

Temperature does a different job. As the oil temperature rises, the viscosity falls and the oil can be sprayed as a fine mist; the finer the mist, the larger the interface between the oil and the vacuum space, and the easier it is for the water and the gas to be drawn off. The temperature control range of the TYA series is 45–80 °C, and the ZYD series is set within the same range. When the temperature is too low, what comes out of the nozzle is a thick stream rather than a fine mist, and the degassing stage is nothing more than a warm tank.

There is a further constraint here: for oil with a high water content the upper temperature limit is pressed down to 70 °C. That is not needed for degassing; it is needed to keep the condition of the oil under control, because a lot of water, a high oil temperature and a long running time are three things that do the oil no good.

The flash evaporation heating section and the temperature control unit
The heating section brings the oil up to the set value and the degassing section pulls the pressure down; the two things are two separate parameters
ParameterValueWhat it decides
Working vacuum-0.08 ~ -0.0999 MPaThe pressure above the oil surface, which sets the low temperature at which water can leave the oil
Ultimate vacuum≤5 PaThe lowest pressure the system reaches in its limit state, used to judge the condition of the system
Temperature control range45–80 °CWhether the oil can be atomised, and with it the area available for the transfer
Upper limit for wet oil70 °CLimits what a high temperature does to the condition of the oil

What the relation between the two is

Put the two side by side and the relation is clear: the vacuum level decides at which low temperature the water can leave the oil, and the heating temperature decides whether the oil can be atomised. The deeper the vacuum, the lower the heating temperature that is needed; if the vacuum level is already there and the temperature does not come up, the atomisation is poor and the degassing result is poor in the same way. When the vacuum level sits at the shallow end, raising the temperature to the top of the range does not help either, because the bottleneck is not the heat transfer, it is the transfer of mass.

So when the water content on site stops falling, the first thing to work out is which side has failed, because the two directions are completely different: if the vacuum is stable and the water content still does not fall, the problem is most likely on the temperature and atomisation side; if the temperature is there and the vacuum will not come up, the problem is on the vacuum system side - the pumps, the pipework, the valves and the seals.

  • Read the vacuum gauge first: with the reading stable above -0.08 MPa and the water content still not falling, the direction to take is the heating and the atomisation.
  • Read the oil temperature next: when the temperature does not reach the set value, check the heating and the temperature control before suspecting the vacuum.
  • When both are in place and the result is still short, go back to the sampling and the test, and judge the water content by GB/T 7600.

The order to adjust in

When these two are adjusted, the order matters more than adjusting both at once. The usual sequence is to pull the vacuum first and confirm that the system is sealed, then bring the temperature up to the set value and hold it for a while so that the oil circulates and is atomised in the vacuum stage. Keep the two phases apart when reading the result: the reading in the vacuum-pulling phase reflects the sealing condition of the system, while the reading in the heating and degassing phase is the working state.

The temperature is set with a reason as well. The two ends of the 45–80 °C range stand for different trade-offs: towards the 45 °C end the viscosity is on the high side and the atomisation is less good; towards the 80 °C end the atomisation conditions are better, but more is demanded of the condition of the oil. For oil with a high water content, or for a long continuous run, pressing the upper limit down to 70 °C is the more workable choice.

The vacuum level decides at which low temperature the water can leave, the temperature decides whether the oil can be atomised; get one of the two right and the water is still in the tank.