There is one kind of site whose logic is completely different from that of a substation: an industrial plant that runs continuously. Such a plant cannot stop in order to have its oil treated, so the treatment cannot be a job of emptying the system, feeding oil in and degassing it in turn; it can only be hung on the system and run for a long time, either continuously or on a bypass.
What continuous running changes
The most direct change is the rhythm. In intermittent work, a treatment run goes through warm-up, pulling the vacuum, degassing and outlet, and every step can be watched by a person. In continuous running the machine has to work for a long time with nobody watching it, and the states - temperature, oil level, foam and pressure - all have to be looked after by something.
This is what automatic control means in continuous operation. The TYA series makes the temperature control a continuous range of 45–80 °C, and with the infrared liquid level and foam detection and the automatic defoaming, not every change of state in the tank has to be watched by hand. The acoustic and visual alarm with automatic shutdown on overpressure is then there to stop the machine when something is wrong, rather than letting it run on until it is damaged.
How the consumables are changed is another condition. Stopping to change a filter element is expensive in continuous running, so the way the elements are arranged matters: the fine elements of the ZYD-100 are five 150-500-5 in parallel, and while one of them is changed the others still keep filtering. That is the room that was left for maintainability under continuous duty.

| Way of working | When the treatment takes place | What it asks of the equipment |
|---|---|---|
| Intermittent treatment | Work with the plant stopped, following the maintenance schedule | The quantity per run comes first, and manual attendance can cover it |
| Continuous treatment | Going on while the plant is running | Automatic control, condition monitoring and interlock protection |
| Bypass treatment | The main line keeps running while a branch circulates and purifies | Control of flow and pressure difference, without disturbing the pressure of the main system |
Where continuous duty tends to go wrong
- Pressure control: the pressure difference across the filtration stage keeps climbing in continuous running, so the overpressure protection has to be reliable, and both the alarm and the shutdown action have to be tested.
- Temperature control: continuous running means the temperature is held for a long time, and the set value and the upper limit have to be chosen for the actual oil; for oil with a high water content the limit is pressed down to 70 °C.
- Foam and oil level: foam appears when air is mixed into the oil, and whether the automatic defoaming actually acts has to be seen in real conditions, not on an indicator lamp.
- Element changes: the parallel branches have to be switched in the right order, otherwise the pressure difference swings at the moment of the change and carries over into the main line.
The difference in the way it is bought
For continuous running the purchasing decision is not about the first cost but about availability over time: the spare part cycle, the supply of consumables, how fast a fault can be answered and whether the site staff can carry out the daily checks on their own. Local spare part supply and the interchangeability of the consumables carry noticeably more weight here than they do in intermittent work.
Writing these conditions into the technical agreement is more useful than comparing prices once during the purchase. The throughput on the parameter sheet says how much the machine can do in one run; whether it can keep doing that much over time is a different question.
One more requirement of continuous running is easy to forget, and it is about records: the operating data has to be kept. Temperature, vacuum level, pressure and the times of element changes, written down per batch, show after a few months which periods were running close to the limits and whether the consumption of consumables was steady. The same records are what a fault discussion with the equipment supplier is based on.
A plant that runs continuously will not stop for oil treatment, so the machine has to keep the state under control by itself for a long time; that is where the protection chain and the parallel elements earn their place.