The TYA series comes in two capacities: the TYA-50 handles 2000 L/h and the TYA-100 handles 4000 L/h. The vacuum stage, the temperature control range and the protection are the same on both, and the difference sits in how much oil one run moves, which is what sets the rhythm of the batches.

The main figures of the two models

Start with this set: the working vacuum is -0.08 MPa, the temperature control range is 45–80 °C (pressed down to 70 °C when the water content is high), a pressure above 0.3 MPa calls for cleaning and an element change, the ambient temperature range is -20~45 °C, and altitude affects the vacuum level. These are the same on both models.

What differs is the rhythm that the throughput brings. 2000 L/h suits a site with a small quantity of oil and many batches: the wait for one batch is short, the intervals between cleaning and element changes are closer together, and the time the operators spend on site is spread thin. 4000 L/h suits a larger quantity of oil and longer intervals between batches: one run occupies the machine for longer, but there are fewer waits.

The buttons, the digital displays, the pressure gauge and the vertical filter housings on the control panel
The continuous temperature control and the operating figures are shown on the panel, and the temperature setting decides the quality of a run
ItemTYA-50TYA-100
Throughput2000 L/h4000 L/h
Working vacuum-0.08 MPa-0.08 MPa
Temperature control range45–80 °C45–80 °C
Upper limit for wet oil70 °C70 °C
Pressure above 0.3 MPaClean and change the elementClean and change the element
Ambient temperature range-20~45 °C-20~45 °C

Why the temperature control is continuous

The temperature control is a continuous range of 45–80 °C rather than a few fixed values because the state of the oil varies a great deal. Oil with a high viscosity needs a higher temperature before it atomises well, and oil with a lot of water, or a long continuous run, calls for the upper limit to be pressed down to 70 °C. A continuous range leaves room for adjustments in both directions.

A continuous range has a second advantage: when the batches differ, the same machine can be run at a different setting for each of them. Oil with a normal water content can be run towards the top of the range, and when a batch with a higher water content comes along the setting can be brought down, so the machine itself does not have to be reconfigured for the sake of one batch. Because the temperature control can be set continuously, the site does not have to choose between a few fixed values.

The setting also has to be read together with the pressure. A pressure above 0.3 MPa calls for cleaning and an element change, which means the filtration stage can no longer build up a normal pressure difference; heating further at that point is no use, the elements and the filter cloth have to be dealt with first, and only then do the temperature and the flow return to a normal state.

The rhythm of cleaning and element changes

The two capacities consume their consumables at different rates. More oil passes through the larger machine in the same time, the elements load up faster, and the time it takes for the pressure difference to reach 0.3 MPa is shorter; the smaller machine works its elements for longer on the same quantity of oil, but the batches change more often and the machine is opened and closed more often.

Once the rhythm is worked out, the site knows how to schedule: when to set aside time for cleaning and an element change, whether the machine can be stopped during that time, and if it cannot, whether the spare element is prepared in advance or the work is moved into a different maintenance window. Those arrangements do not come from the machine parameters; they come out of the parameters and the quantity of oil and the shifts on site being put together.

Four questions to ask the site before choosing

  • How much oil is to be treated each time, and how long is the interval between the batches: this decides between 2000 L/h and 4000 L/h.
  • What the state of the oil is now: the water content, the breakdown voltage and the cleanliness are measured first, and for oil with a high water content the upper temperature limit is pressed down.
  • The temperature and the altitude of the site: an ambient temperature within -20~45 °C is the design condition, and anything outside that range has to be confirmed separately.
  • Whether the machine runs continuously or intermittently: continuous running asks more of the automatic control, the condition monitoring and the interlocks.

How to use them

The difference between the two models ends up in the rhythm. With small batches and a need for a quick result, the 2000 L/h model is the more flexible one; with large batches and a wish to get it right in one run, the 4000 L/h model saves the waiting. The figures on the parameter sheet are the capability, the rhythm is worked out on site, and the two have to be read together when a model is chosen.

The TYA-50 and the TYA-100 do not differ in the temperature control or in the vacuum stage, they differ in how much oil one run moves; what is actually being chosen is the rhythm of the batches.