The pump set is one of the parts of a machine that fails most often, and replacing a pump is not difficult in itself, but afterwards there are often deviations that cannot be explained: the flow does not come up, the vacuum becomes shallower, the pressure builds slowly, or the motor sounds different. Most of these deviations are not about the quality of the new pump, they come in with the reinstallation.

The connections: measure before fitting

The part that most often goes wrong when a pump is changed is not the pump itself but the connection. Pipe diameter, flange standard, thread size and the direction of the inlet and outlet have to match; if they do not, either a temporary adapter is needed or the pipework has to be modified on site. The extra joint section that a modified pipework leaves behind is a new leak point and a source of pressure drop. The way to confirm the connection is direct: compare the mounting dimensions and the nameplate of the old pump, check that the inlet and outlet positions and the pipe diameters of the new pump are the same, and then decide whether to fit it as it is or to change the pipework.

The direction has to be checked at the same time. The screw oil pump ZH and the vacuum pump X-100 do completely different work, one sends the oil to the filtration stage and the other draws the vacuum. Fitted the wrong way round or turning the wrong way, the symptoms are not obvious: an oil pump turning the wrong way may simply not pump, and a vacuum pump fitted the wrong way may produce no negative pressure at all.

The seals: every joint that was opened is a new risk

When a flange is put back, whether the sealing face was cleaned, whether the gasket was fitted as required and whether the bolts were tightened to the specified torque decide whether that section can still hold a vacuum. A sealing problem shows up first as a vacuum that becomes shallower, and it becomes shallower slowly: it is close to normal right after the work and the reading drifts upwards as the machine runs.

A sealing problem also appears in another form, as oil seeping at a pipe connection. Seeping and leaking have to be told apart: oil seeping from a static seal means that section is slowly losing its seal, while droplets at a moving seal are usually a mechanical matter, connected with the alignment or the mounting state when the pump was changed.

The position of the pump set and the coupling on the oil purifier
The pump set, the coupling and the pipe connections are the three places that need to be checked first after a pump change
Item to checkWhat a normal result looks likeWhere to look when it is not
Inlet and outlet connectionsThe pipe diameters and flanges match, with no temporary adapterThe joint section left by a modified pipework, the temporary adapter
Direction of rotationThe pump runs in the marked direction and the sound is steadyThe phase sequence of the wiring, the direction mark
Flange sealingThe vacuum level stays stable after the workThe sealing face, the gasket, the tightening torque
Coupling alignmentNo periodic vibration while the machine runsThe alignment, the load on the base frame

Four checks once the pump is back

  • Pull a vacuum once: with the system not connected to the oil, pull down and see where the reading settles, which is the most direct way of judging whether the sealing is in order.
  • Run one round at the rated flow: see how far the actual flow is from the rated figure (6000 L/h for the ZYD-100), and when the deviation is clear, check the rotation and the resistance of the pipework first.
  • Confirm that the protection still works: the acoustic and visual alarm with automatic shutdown on overpressure and the phase failure and phase sequence protection have to be confirmed again after a pump change, because wiring was moved.
  • Record the change in the parameters: put the vacuum level, the current and the temperature from before and after the work side by side; a deviation that persists is proof that something was left in place during the fitting.

A pump change is not the end of the job

The pump is one link in the oil line and in the vacuum chain, and after a change the assumption that is easiest to relax is that the new pump is a good one. In fact the change touched three things at once, the connections, the seals and the wiring, and if any one of them is not right the symptoms all land on the new pump.

Do not judge the new pump before the connections, the seals and the rotation have been checked; until they have, the fault keeps being recorded against the new pump.