When the machine has stopped and two or three indicators are lit on the control cabinet, the usual response on site is to work through the manual one item at a time. The manual is written one item at a time, but what happens on site is several lines tangled together. Those lines have an order, and once it is seen, deciding what to handle first is no longer difficult.

Sort the alarms into three classes by what they protect

The first class protects electrical safety and the machine itself: phase failure and phase sequence protection, and the audible and visual overpressure alarm with shutdown. The action here is the hardest of the three, because it cuts the run outright. The second class protects the state of the medium inside the chamber: infrared level detection and foam detection, with automatic foam suppression. Their purpose is to keep the inflow under control and to stop foam from reaching the vacuum system. The third class is not an alarm at all but the result indicators: water content ≤3 ppm (GB/T 7600), gas content ≤0.01% (GB/T 423), breakdown voltage ≥65 kV (GB/T 507), cleanliness NAS 1638 class 5. These four come from a sampled test, and they do not appear on the panel when the machine stops.

Separating the third class from the alarms is important. Adjusting the temperature control or changing the vacuum setting after a shutdown is usually wasted work.

A grey frame-mounted machine in the workshop with three horizontal filter canisters beside the horizontal tank and a control cabinet on the right carrying a digital display, red and green indicators and a red audible and visual alarm beacon
The indicators and the audible and visual alarm on the cabinet protect different things, so read which one is active first
Alarm or indicationWhat it protectsActionWhat to check first
Phase failure / phase sequence protectionThe motor and the electrical circuitRefuses to start, or stops the machineThe three-phase voltage at the incoming line and the tightness of the terminals
Audible and visual overpressure alarmThe chamber and the whole oil circuitSounds and lights up, then stops the machineWhether the resistance of the elements has risen or the pump has stopped
Infrared level detectionThe oil level inside the chamberLimits the inflowWhether the level matches reality and whether the probe is fogged with oil mist
Foam detection with automatic suppressionThe inlet of the vacuum systemSuppresses the foam or limits the inflowThe gas content of the incoming oil and whether the atomisation is normal

Three dependency chains that are seen often

The first runs from the supply to the pump to the pressure and on to the flow rate. With no power, or with a phase missing, the pump does not turn, nothing moves in the oil circuit, the differential pressure does not rise and the flow rate is zero. On this chain, if the upstream is blocked, every reading downstream is only a secondary effect.

The second runs from the oil temperature to the atomisation to the vacuum level and on to the gas content. If the oil has not reached its set temperature, the atomisation stays incomplete, the oil film cannot be made thin, the negative pressure cannot be established and the gas stays in the tank. The working vacuum is -0.08 ~ -0.0999 MPa, so when the vacuum will not come up, check whether the oil has reached its temperature before you look at the pipework and the pump group.

The third runs from the level and the foam to the inflow to the chamber pressure and on to the overpressure shutdown. When the inflow rate exceeds what the chamber can take, the level rises, foam builds up, the pressure inside the chamber rises with it and the audible and visual overpressure alarm finally stops the machine. On this chain the inflow rate is the quantity that can be controlled: temperature, oil volume and the opening of the inlet valve all affect it.

  • When two alarms appear at the same moment, look at which one is upstream: if the upstream is blocked, the downstream symptom needs no separate handling.
  • When an alarm action and an abnormal reading appear together, first ask whether the reading is the result of the alarm rather than its cause.
  • When an abnormality is still there after the shutdown, work upstream in order instead of resetting repeatedly at the downstream end.

Fixing the order is worth more than memorising every alarm

The alarm points are not identical on every model, and it is not easy to obtain a handling card that covers all of them. What actually works is to write the three chains above for the machine on hand on a sheet next to the operating position, marking the corresponding gauge and the corresponding action. Written down it is more reliable than kept in memory, and it survives a change of staff.

Do not rush to reset after a shutdown: work down the dependency chain from the upstream. If the upstream is left alone, the downstream keeps alarming.