Once the machine has been installed, the first time it is energised and the first time oil comes out are best worked through as six fixed steps. Each step has readings to confirm and a basis for judging them, and once the six are done the machine has a baseline, and every later comparison starts from that baseline.
The six steps
The first step is the power and the earthing. Check that three-phase 380V / 50Hz matches the nameplate, tighten the incoming terminals and the terminal strip inside the cabinet one by one, and check the door seal and the interlock. Phase failure and phase sequence protection are fitted to the machine; this check is what makes sure they act when they are really needed.
The second step is the pipework and the valves. Walk through the oil inlet, the return, the drain and the discharge one by one, check that the opening and closing direction of every valve agrees with the direction of the pipework, and check that no blind plate or debris blocks the line. Until the pipework has been dealt with, none of the later readings mean anything.
The third step is heating. Set the temperature control within the 45–80 °C range, with the upper limit pressed down to 70 °C for oil with a high water content. After energising, watch whether the temperature settles at its set value. If it will not rise, do not judge the machine yet: check the supply, the heating circuit and the quantity of oil in the machine.
The fourth step is pulling the vacuum. The working vacuum is -0.08 ~ -0.0999 MPa; once it is steady within that range, move on to the next step. If it will not come up, look at the pump group, the sealing of the pipework and whether there is residual liquid in the chamber, and do not start by adjusting the set value.
The fifth step is feeding the oil and the atomisation. Feed a small quantity of oil and watch how it atomises in the chamber and whether the level rises as it should. The infrared level detection and the foam detection are both verified at this step, and if either gives an abnormal reading, stop feeding.
The sixth step is the discharge and the readings. Check the flow rate against the rated conditions, and the ZYD-100 is 6000 L/h. At the same time confirm that the outlet pressure and the differential pressure across the filtration section are within their normal range.

| Step | What to confirm at this step | The basis for judging it |
|---|---|---|
| One, power and earthing | Three-phase 380V / 50Hz, tightened terminals, cabinet door interlock | Agreement with the nameplate |
| Two, pipework and valves | Oil inlet, return, drain and discharge | The direction agrees with the valve positions |
| Three, heating | Temperature control 45–80 °C, upper limit 70 °C for wet oil | The temperature settles at its set value |
| Four, pulling the vacuum | Working vacuum -0.08 ~ -0.0999 MPa | Steady within the range |
| Five, feeding oil and atomisation | State of the atomisation, level, foam | No abnormality on the infrared level or foam detection |
| Six, discharge and readings | Flow rate 6000 L/h, outlet pressure | The readings under rated conditions |
The records to keep after the first run
Four readings: the oil temperature, the vacuum level, the outlet pressure and the flow rate. These four numbers are the initial baseline of this machine, and after every shutdown and overhaul, every element change and every batch of a different oil, they are the four numbers to come back to. How far they have moved, and in which direction, is the basis for the judgement.
Then take one sample and send it for testing, and set the result beside the parameters: water content ≤3 ppm (GB/T 7600), gas content ≤0.01% (GB/T 423), breakdown voltage ≥65 kV (GB/T 507), cleanliness NAS 1638 class 5. These four are the results this machine reaches under the parameters it left the factory with, and the first run is already enough to compare them, which is the earliest confirmation of the state of the machine.
The three things most easily missed on a first run
- Do not fill the chamber on the first run. With a small quantity of oil the temperature rises quickly and problems show themselves easily; once the chamber is full, finding a problem costs far more.
- Do not skip the sample and the testing on the first run. Looking only at the instruments and not at the data means a filter element fitted the wrong way or a cross-connected oil line is not found until the next oil change.
- Keep the records of the first run with the delivery documentation. Only with the baseline records and all the later records in one place can the changes in this machine be followed.
The aim of the first run is not how much oil it produces but how well the initial state of the machine is recorded. With a baseline, every later judgement has something to rest on.