The total power on the nameplate is an upper limit for the whole machine, while the electricity actually consumed during operation concentrates on a few sections. To work out what this machine costs to run, the first step is not to fetch the electricity bill but to split the power of the machine itself into several parts and measure them one by one.
The total power hides two completely different kinds of load
The total power of the ZYD-100 is 72 + 5 kW and the supply is three-phase 380V / 50Hz. The way it is written means two loads, not a single machine of 77 kW. Which group is the heating and which group is the pump group is settled by the circuit diagram in the accompanying documents, and it should not be guessed from experience.
The reason for separating them is that the two run in completely different ways. The heating is a continuous load: once the temperature has reached its set value, the heater keeps switching on and off around the differential band. The pump group follows the process, so the load changes as the machine goes through filling, circulation and discharge. Mixed together, the two can never be separated in an energy account.

Three methods, from rough to precise
- Clamp meter on the incoming line: clamp the cable and read the total current. This is the simplest method and it answers how much the machine is drawing right now, but it cannot separate the heating from the pump group.
- Separate meters per circuit: fit a sub-meter on the heating circuit and another on the pump group circuit, then read what each of them has registered after one batch of oil. The cost is a one-off investment and the conclusion is the most reliable.
- Shutdown difference method: switch off the loads that can be switched off separately, one at a time, and write down a reading each time. This is the cheapest way, and the difference between two readings is the actual power of the section that was switched off.
| Method | What it reads | The question it answers | Its limitation |
|---|---|---|---|
| Clamp meter | Total current and the power derived from it | How much the machine is drawing now | It cannot break the load down |
| Sub-meters per circuit | The accumulated energy of each circuit | How much each section of the load used | Meters have to be fitted |
| Shutdown difference | The difference before and after switching a section off | Roughly how large that section of the load is | It gives only the difference at that moment |
The four items that have to be written down with every reading
A current value on its own is meaningless three months later. Write four things with every reading: the oil temperature, the ambient temperature, how long the machine has been running, and how many rounds of this batch of oil have been processed. The ambient temperature varies within -20–45 °C, and it directly changes how much heat the heating section has to make up. The position of the oil temperature within the 45–80 °C control range decides whether the heater has just switched or has already settled.
A TYA-100 handling a task at 4000 L/h and a mobile unit such as the TYG-100 spread their running hours over a day in completely different ways, and the LY-200 with its 4800 L/h and its 11 kW motor produces a load curve of yet another shape when it stands in the same workshop as the ZYD series. Only with these figures side by side does it become possible to draw up an energy account that means something.
What the account finally decides
First, how a machine is stopped under intermittent duty: whether the temperature is held or the power is cut altogether. The difference between those two in consumption depends on knowing how large a share the heating section takes. Second, how long the maintenance window has to be: once the load of each section is known, the running time needed for one batch of oil can be estimated. Third, how machines of the same model are combined: one unit or two, depending on whether the duty curve is flat or peaked.
An energy account is not the result of a single measurement. The first measurement gives the character of this machine; what is meaningful is a series of measurements of the same machine under different conditions: winter and summer, continuous and intermittent operation, new oil and heavily contaminated oil. Four sets of readings are what make a comparison possible.
The total power is the ceiling and the split power is the expense. To work out what this machine costs in electricity, the first step is to take 72 + 5 kW apart and measure it.